Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Transl Radiat Oncol ; 46: 100769, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38586079

RESUMO

Purpose: The urethra is a critical structure in prostate radiotherapy planning; however, it is impossible to visualise on CT. We developed a surrogate urethra model (SUM) for CT-only planning workflow and tested its geometric and dosimetric performance against the MRI-delineated urethra (MDU). Methods: The SUM was compared against 34 different MDUs (within the treatment PTV) in patients treated with 36.25Gy (PTV)/40Gy (CTV) in 5 fractions as part of the PACE-B trial. To assess the surrogate's geometric performance, the Dice similarity coefficient (DSC), Hausdorff distance (HD), mean distance to agreement (MDTA) and the percentage of MDU outside the surrogate (UOS) were calculated. To evaluate the dosimetric performance, a paired t-test was used to calculate the mean of differences between the MDU and SUM for the D99, D98, D50, D2 and D1. The D(n) is the dose (Gy) to n% of the urethra. Results: The median results showed low agreement on DSC (0.32; IQR 0.21-0.41), but low distance to agreement, as would be expected for a small structure (HD 8.4mm (IQR 7.1-10.1mm), MDTA 2.4mm (IQR, 2.2mm-3.2mm)). The UOS was 30% (IQR, 18-54%), indicating nearly a third of the urethra lay outside of the surrogate. However, when comparing urethral dose between the MDU and SUM, the mean of differences for D99, D98 and D95 were 0.12Gy (p=0.57), 0.09Gy (p=0.61), and 0.11Gy (p=0.46) respectively. The mean of differences between the D50, D2 and D1 were 0.08Gy (p=0.04), 0.09Gy (p=0.02) and 0.1Gy (p=0.01) respectively, indicating good dosimetric agreement between MDU and SUM. Conclusion: While there were geometric differences between the MDU and SUM, there was no clinically significant difference between urethral dose-volume parameters. This surrogate model could be validated in a larger cohort and then used to estimate the urethral dose on CT planning scans in those without an MRI planning scan or urinary catheter.

2.
Int J Radiat Oncol Biol Phys ; 118(3): 682-687, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37776979

RESUMO

PURPOSE: Ultrahypofractionated radiation therapy (UHRT) is an effective treatment for localized prostate cancer with an acceptable toxicity profile; boosting the visible intraprostatic tumor has been shown to improve biochemical disease-free survival with no significant effect on genitourinary (GU) and gastrointestinal (GI) toxicity. METHODS AND MATERIALS: HERMES is a single-center noncomparative randomized phase 2 trial in men with intermediate or lower high risk prostate cancer. Patients were allocated (1:1) to 36.25 Gy in 5 fractions over 2 weeks or 24 Gy in 2 fractions over 8 days with an integrated boost to the magnetic resonance imaging (MRI) visible tumor of 27 Gy in 2 fractions. A minimization algorithm with a random element with risk group as a balancing factor was used for participant randomization. Treatment was delivered on the Unity MR-Linac (Elekta AB) with daily online adaption. The primary endpoint was acute GU Common Terminology Criteria for Adverse Events version 5.0 toxicity with the aim of excluding a doubling of the rate of acute grade 2+ GU toxicity seen in PACE. Analysis was by treatment received and included all participants who received at least 1 fraction of study treatment. This interim analysis was prespecified (stage 1 of a 2-stage Simon design) for when 10 participants in each treatment group had completed the acute toxicity monitoring period (12 weeks after radiation therapy). RESULTS: Acute grade 2 GU toxicity was reported in 1 (10%) patient in the 5-fraction group and 2 (20%) patients in the 2-fraction group. No grade 3+ GU toxicities were reported. CONCLUSIONS: At this interim analysis, the rate of GU toxicity in the 2-fraction and 5-fraction treatment groups was found to be below the prespecified threshold (5/10 grade 2+) and continuation of the study to complete recruitment of 23 participants per group was recommended.


Assuntos
Gastroenteropatias , Neoplasias da Próstata , Humanos , Masculino , Imageamento por Ressonância Magnética , Pelve , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/patologia , Sistema Urogenital/efeitos da radiação , Ensaios Clínicos Controlados Aleatórios como Assunto , Ensaios Clínicos Fase II como Assunto
3.
Cancers (Basel) ; 15(4)2023 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-36831631

RESUMO

Several studies have demonstrated the association between acute and late radiotherapy toxicity in prostate cancer using older radiotherapy techniques. However, whether this association is present with newer techniques such as stereotactic body radiotherapy (SBRT), remains unclear. We use univariable and multivariable logistic regression to analyse the association between grade 2 or worse acute gastrointestinal (GI) and genitourinary (GU) toxicities with equivalent late toxicities in patients treated with SBRT and conventional or moderately fractionated radiotherapy (CRT) within the PACE-B study. 842 patients were included in this analysis. Common Terminology Criteria for Adverse Events (CTCAE) was the primary clinician reported outcome measure used in this analysis. In univariable analysis, experiencing a grade 2+ acute GU toxicity was significantly associated with developing a grade 2+ late GU toxicity after SBRT (OR 4.63, 95% CI (2.96-7.25), p < 0.0001) and CRT (OR 2.83, 95% CI (1.69-4.71), p < 0.0001). This association remained significant in multivariable analysis. In univariable analysis, experiencing a grade 2+ acute GI toxicity was also associated with developing a grade 2+ late GI toxicity after SBRT (OR 3.67, 95% CI (1.91-7.03), p < 0.0001) and CRT (OR 4.4, 95% CI (2.04-9.47), p < 0.0001). This association also remained significant in multivariable analysis. Grade 2+ baseline GU symptoms were also associated with grade 2+ late urinary toxicity in both univariable and multivariable analysis. Overall, acute toxicity is an important predictor variable for late GU/GI toxicity after localised prostate radiotherapy using SBRT and CRT. Future work should test whether optimising symptoms pre-treatment and early intervention in those with significant acute toxicities could mitigate the development late of toxicity.

4.
J Immunother ; 43(2): 53-56, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31567705

RESUMO

It remains unclear whether targeted next-generation sequencing (tNGS) conveys a reliable estimate of tumor mutational burden (TMB). We sequenced 79 archival samples of immune checkpoint inhibitors (ICPIs) recipients (57% lung cancer, 43% melanoma) using Ion Ampliseq Cancer Hotspot Panel. Employing multiple cutoff values, we verified that TMB by tNGS did not correlate with response or survival following ICPI. We found enrichment of ATM mutations in ICPI-refractory tumors (P=0.01) to correlate with worse survival (4.2 vs. 10 mo, P=0.03). Limited-coverage tNGS delivers an imprecise estimate of patients' TMB but may aid identification of candidate somatic variants of predictive/prognostic significance.


Assuntos
Inibidores de Checkpoint Imunológico/uso terapêutico , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/genética , Melanoma/tratamento farmacológico , Melanoma/genética , Mutação/genética , Carga Tumoral/genética , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais/genética , Feminino , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Humanos , Imunoterapia/métodos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Prognóstico , Linfócitos T/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...